 |
Rebar is commonly fabricated after galvanizing. In order to minimize the possibility for coating damage, avoid bending the rebar at a radius of more than 8 times its radius. ASTM A 767, Specification for Zinc-Coated (Galvanized) Steel Bars for Concrete Reinforcement, has a table that provides maximum bend diameters for various-sized rebar.
|